Beninca Brain 24 Manual. Instruction Manual for Beninca Brain 24 Control Panel. Copy to Email · Send to Mobile. Print. Download · Buy Product. Name. 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 8k2 Command central for 1/2 24Vdc motor, for single or sliding doors: BRAINY Beninca Brain 24 – EasyGates Manuals & Guides. L Rev. 02/06/02 CENTRALE DI COMANDO CONTROL UNIT STEUEREINHEIT CENTRALE DE.

Author: Faurn Netaxe
Country: Mayotte
Language: English (Spanish)
Genre: Travel
Published (Last): 6 January 2005
Pages: 78
PDF File Size: 11.71 Mb
ePub File Size: 8.95 Mb
ISBN: 766-3-13748-943-2
Downloads: 84563
Price: Free* [*Free Regsitration Required]
Uploader: Zologrel

Confirmation of operation is required. Parameters, Logic and Special Functions The tables below describe the individual functions available in the control unit.

With the gate open or in the opening phase the intervention of the photocell causes automatic closing after 3 s. One segment of the display is linked to each input.

OFF Blc The lock function is enabled or disabled. The parameters menu allows you to assign a numerical value to a function, in the same way as a regulating trimmer.

Limit switches not provided. Page 6 only by the triggering of the limit switch or by the amperometric sensor. If the code is valid, it is stored in memory and OK appears. Page 5 The logic menu allows you to activate or deactivate a function, in the same way as setting a dip-switch. Contact controlled by 2nd radio channel of the receiver. Active only with TCA: RTR Completely erase the receiver memory.

Beninca Brain 24V PCB Board and Casing

OFF serL Service light function is enabled or disabled on output Other special functions follow the parameters and logic menus and may vary depending on the type of control unit or the software release.

  ALLTAG BERUF CO 3 LEHRERHANDBUCH PDF

Adjustment of braking With braking enabled SLD logic: For example, with a 20s stroke, preset 17s to start the braking btain, 3s in advance with respect to end of movement.

The step-by-step impulse or transmitter impulse has no effect during the opening phase. Receiver enabled for rolling-code and programmable beninva transmitters self-learning and Dip Switch. Radio receiver enabled only for rolling-code transmitters. Example of programming Let us suppose it is necessary to: Press the transmitter key to be assigned to this function.

The brxin time should therefore be lower than the real stroke of the operator.

Beninca Brain 24V PCB Board and Casing

After waiting 60s the control unit quits programming mode and switches off the display. Page of 9 Go. By pressing ‘print’ button you will print only current page. If the code is not valid, the wording Err is displayed. The transmitter codes are not erased brajn the receiver.

To use this function, close the grain switch contacts with jumpers. Add to my manuals Add. If the code is valid, it is erase and OK appears.

OFF mloc Selects the type of electric lock used. The operation mode of the amperometric sensor is selected ei- ther the limit switches are provided or not.

Don’t have an account? The operating time is adjusted at normal speed during motor 1 opening and closing phases. The output has the function of 2nd radio channel: Make sure the devices are correctly connected i.

  LAGHU SIDDHANTA KAUMUDI ENGLISH PDF

If the code is not valid or is not in memory, the wording Err is displayed. The speed of the motor during braking is determined by the SLDS parameter value. If buffer batteries are used, connect behinca CB. The amperometric sensor activation is interpreted by the control unit as limit switch.

Got it, continue to print. Comply with regulations in force! Electric lock with latch, normally not fed. Control Unit Beninca CP. Receiver enabled for rolling-code and programmable code transmitters self-learning and Dip Switch. It’s a community-based project which helps to repair anything. Comments to this Manuals Your Name.

OFFas the end of operation is determined 11 only by the triggering of the limit switch or by the amperometric sensor. The speed of the motor during braking is determined by the SLDS parameter value.

Similarly to the safety edge activation, the control signal is sent to stop and reverse movement for approx. Only motor 1 operating.

The amperometric sensor activation is braln by the control unit as obstacle present in the gate movement area. In the event of failure it switches on according to the following scheme.

To print the manual completely, please, download it. The value is expressed in percentage with respect to speed during normal operation.